Project 24.06 AJSD Sewer Replacement. Specifications are available at www.ajsewer.org or by contacting the District at (480) 941-6767. All bids are due Thursday, June 20, 2024 at 10:00 AM.
Question 1: What kind of permits do we need to furnish?
Answer 1: No permits needed.
Question 2: Besides staking, do we need to provide compaction test?
Answer 2: No compaction testing required.
Question 3: Shall Sewer Bypass be provided between existing SSMH #1 and SSMH #6? If so, does the existing 8" Sewer-line flow 24/7 and what is the sewage capacity?
Answer 3: Yes, flows are 24/7 and anticipated sewer capacity is 20,000 gallons per day.
Question 4: Does the entire existing 8" Sewer-line between existing SSMH #1 and SSMH #6 (except the removal portions) need to be filled with grout?
Answer 4: No, only the small stub sections required to be filled; the remainder will be abandoned in place.
Question 5: Are we responsible for existing above ground improvement replacements including the three removed trees?
Answer 5: Trees or other above ground improvements do not need to be replaced.
06/03/2024 - DCS Contracting
Question 1: I am reaching out about the Apache Junction Sewer District Sewer Replacement project, number 24.06. Will the submission of this bid require a bid bond? I did not see mention of one in the bid package but wanted to be absolutely clear that if is or is not required to bid this project.
Answer 1: The District does not require a bid bond for submission.